Introduction. Radiographic assessment of hallux valgus is based on measurements of the hallux valgus angle (HVA), intermetatarsal angle (IMA), and hallux interphalangeal angle (IPA) on standing anteroposterior foot radiographs. These parameters are important for evaluating deformity severity and planning
surgical treatment. However, semi-automated methods are time-consuming and susceptible to observerdependent variability. AI-based automation may improve measurement reproducibility and facilitate preoperative planning.
Aim. To develop an automated artificial intelligence-based system for measuring HVA, IMA, and IPA on weight-bearing foot radiographs, and to assess the agreement, analysis time, and clinical usefulness of automated measurements compared with semi-automated measurements.
Materials and methods. A total of 265 weight-bearing anteroposterior foot radiographs from patients qualified for surgical treatment were analyzed. After training a neural network for segmentation and labeling of foot bones, with segmentation accuracy expressed by a Sørensen–Dice coefficient > 0.97, reference points were automatically determined, and HVA, IMA, and IPA were calculated. Automated measurements were compared with semi-automated measurements performed by orthopedic surgeons. Agreement, accuracy, and reproducibility were analyzed using the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and Bland–Altman analysis. For IPA, Pearson correlation, mean absolute error, limits of agreement, and measurement time were additionally assessed. Agreement regarding the recommended type of surgical procedure based on HVA and IMA values obtained using both methods was also compared.
Results. Automated measurements showed high agreement with semi-automated measurements. Comparison of the AI system with semi-automated measurements demonstrated high ICC values for HVA (0.97), IMA (0.89), and IPA (0.88–0.92), with corresponding SEM values of 0.26, 0.16, and 1.77°–2.09°, respectively. Bland-Altman analysis showed small systematic biases between methods, amounting to 0.13° for HVA, 1.87° for IMA, and 1.61–2.54° for IPA. For IPA, Pearson correlation coefficients between automated and semi-automated measurements were r = 0.85–0.90 (p < 0.001). Automated IPA assessment in 84 cases took approximately 4.5 minutes, compared with 36 minutes for semi-automated measurements. Agreement between surgical recommendations based on automated and semi-automated HVA and IMA measurements was 0.80.
Conclusions. The developed artificial intelligence-based system enables fully automated, fast, and reproducible measurement of HVA, IMA, and IPA on foot radiographs. The U-Net-based bone segmentation method demonstrated high accuracy and good agreement with clinicians’ assessment, including in cases of
advanced deformity. The system may shorten analysis time, reduce measurement variability, and support clinicians in the diagnosis and surgical planning of hallux valgus.
Introduction. Tibial bone defects represent a significant challenge in primary total knee arthroplasty (TKA), compromising structural integrity and implant durability. Hence, we developed a novel algorithm incorporating defect depth, proportional plateau involvement, containment, and metaphyseal involvement and studied its outcome and efficacy to standardise the management of tibial bone defects in primary TKA. Materials and methods. Sixty-four patients undergoing primary TKA at Yenepoya Medical College were managed using an intraoperatively developed algorithm categorising 5 treatment options. The patients were assessed for radiological parameters, including cement-bone integration, component migration, and deformity progression, while clinical parameters assessed included pain, ROM, patellar tracking, quadriceps strength and gait pattern. Outcome measurements were assessed using KOOS and WOMAC scores at intervals of 3, 6, 12, and 24 months. Results. Overall, 93.75% of patients achieved good-to-excellent outcomes with corrected mechanical hipknee-ankle angles maintained within normal range in 82.81% of cases. Cement mantle adequacy exceeded 90% across all groups. Mean knee flexion exceeded 100° in all groups at final follow-up, with 79.68% of patients achieving normal gait and 93.5% resuming activities of daily living. Patient satisfaction scores exceeded 8.5, and revision surgery was required in only 4 patients. Functional assessment using KOOS and WOMAC scores demonstrated significant improvements from baseline across all treatment groups. Conclusions. Algorithmic management of defects based on depth, surface area, containment and metaphyseal involvement provides a 3-dimensional overview for defect assessment. It optimises the management strategy, yielding superior clinical and radiological outcomes, enhancing component stability, and long-term durability.
Introduction. Proximal femoral fractures (PFF) are a common and serious problem in older adults, associated with high mortality and loss of functional independence. Despite advances in surgical treatment, outcomes remain suboptimal. This study aimed to assess how perioperative factors, such as the timing of surgery, time of day, surgeon experience, operative duration, and hospital length of stay, affect mortality and quality of life after PFF. It also compared outcomes between femoral neck and intertrochanteric fractures. Quality of life was assessed using the EQ-5D-5L questionnaire. This study analyses the role of organisational and clinical factors in treatment outcomes, considering both mortality and functional recovery.
Materials and methods. This retrospective study included 125 patients aged ≥65 years who underwent surgery for low-energy PFFs between 2020 and 2021. The study analysed how perioperative factors such as timing of surgery, surgeon experience, operative duration, and hospital stay length affect mortality and treatment results. Mortality was assessed at 0–1, 1–3, and >3 years after surgery. Quality of life was evaluated using EQ-5D-5L at the 4-year follow-up. Outcomes were compared between femoral neck and intertrochanteric fractures. Non-parametric tests were used, with p < 0.05 considered significant.
Results. No significant association was found between time to surgery and 3-year mortality. In intertrochanteric fractures, mortality was 56.0% (<48 h) vs 44.7% (>48 h), and in femoral neck fractures, 60.9% vs 52.6%, with no significant differences over follow-up. No significant effect of the time of day of surgery on mortality was observed, although lower mortality was noted before 14:30 in intertrochanteric fractures (40.6% vs 58.1%) and similar rates in femoral neck fractures (55.6% vs 56.2%). Surgeon experience did not significantly influence mortality (intertrochanteric: 45.5% vs 51.2%; femoral neck: 60.6% vs 50.0%). Operative time and hospital stay were not associated with time of death (p > 0.05). For EQ-5D-5L, no significant differences were found for time to surgery; however, higher values were observed after 14:30 (0.895 vs 0.740; p = 0.060) and among specialist-operated patients (0.877 vs 0.663; p = 0.087).
Conclusions. No significant effect of perioperative factors on mortality or quality of life after PFFs was observed. A non-significant trend towards better EQ-5D-5L outcomes was observed among patients operated on after 14:30 and those operated on by specialist surgeons.
Background. Total knee arthroplasty (TKA) is an effective treatment for end-stage knee osteoarthritis, but
a substantial proportion of patients remain dissatisfied after surgery. Robotic-assisted TKA (RA-TKA) has been introduced to improve implant positioning, alignment accuracy, and intraoperative reproducibility, yet its true clinical value remains debated.
Objective: To provide an updated, clinically focused review comparing RA-TKA with conventional TKA with respect to radiographic accuracy, functional outcomes, safety, learning curve, and economic considerations.
Methods. This manuscript was revised as a structured narrative review. Literature from PubMed, Scopus, Web of Science, and Google Scholar was prioritized with emphasis on systematic reviews, meta-analyses, randomized controlled trials, and comparative cohort studies evaluating primary RA-TKA for knee osteoarthritis. Evidence was synthesized narratively across key outcome domains. Transparent review reporting principles were aligned, where applicable, with PRISMA 2020.
Results. Current evidence consistently shows that RA-TKA improves component positioning accuracy and reduces alignment outliers when compared with conventional instrumentation. However, superiority in patient-reported functional outcomes, range of motion, and long-term survivorship has not been demonstrated consistently. Some comparative studies indicate reduced early pain and shorter length of stay, whereas operative time is usually longer and economic benefit appears strongly volume-dependent.
Conclusions. RA-TKA currently offers the greatest advantage in surgical precision, although it does not demonstrate markedly superior short- to medium-term clinical outcomes. The best-supported conclusion is that robotic systems improve alignment fidelity. In contrast, their broader clinical and economic value likely depends on platform type, surgeon experience, institutional volume, and longer-term follow-up.
Background and purpose. Artificial intelligence (AI) is increasingly used across orthopaedic care, from imaging and preoperative planning to robotic surgery, rehabilitation, and outcome prediction. Most reviews organise this literature by technology or subspecialty, giving limited insight into how AI is integrated across
the patient pathway or how health systems shape its translation into practice. AI adoption in Poland was compared with two European leaders in digital orthopaedics, Sweden and the United Kingdom.
Methods. A narrative review of peer-reviewed literature, national registry reports, implementation studies, and digital health policy documents were performed and synthesised across four domains: (1) preoperative AI (diagnosis, imaging, surgical planning); (2) perioperative AI (navigation, robotics, intraoperative decision
support); (3) postoperative AI (rehabilitation, remote monitoring, outcome prediction); and (4) national AI ecosystems (registry infrastructure, governance, translational readiness).Results. Three distinct national models emerged. The United Kingdom has a nationally coordinated system driven by NHS implementation strategy and registry-linked prediction. Sweden has a data-centric ecosystem built on decades of registries supporting personalised prediction models. Poland has notable strength in telemedicine and digital rehabilitation, while AI-assisted planning, intraoperative support, and registry-enabled learning remain underdeveloped. Shared challenges include external validation, interoperability, explainability, regulatory compliance, and sustainable workflow integration.
Conclusion. Poland, Sweden, and the United Kingdom illustrate three complementary approaches to AI-enabled orthopaedic care. Comparing these ecosystems offers practical, transferable lessons for countries seeking to accelerate the safe translation of AI into routine orthopaedic practice.
The authors reviewed the medical literature on Madelung’s deformity, a rare congenital condition that causes wrist deformity, shortening of the radius, and dorsal subluxation of the distal ulna. This paper was conducted as a narrative review of the literature on treatment options for Madelung deformity.
Methods. A systematic search of the published English literature was performed using the PubMed/MEDLINE, Embase, Scopus, and Google Scholar databases. Articles published in English were included. The search encompassed all available literature through March 2026. Search terms included combinations of
the following keywords and Medical Subject Headings (MeSH), where applicable: “Madelung deformity,” “Madelung’s deformity,” “congenital wrist deformity,” “Vickers’ ligament,” “ulnar shortening,” “wedge osteotomy,” “PROM,” “patient-reported outcome measurements,” “patient-specific instrumentation,” and “dome osteotomy.” Boolean operators (AND/OR) were used to optimize the search. The authors chose 39 publications that met the inclusion criteria. Data were synthesized qualitatively because of heterogeneity in the study design, patient populations, interventions, and reported outcomes.
Conclusion. The overall rarity of Madelung deformity, along with consistently small sample sizes from studies, insufficient follow-up data, and diverse surgical solutions, has led to no clear agreement on a single ideal intervention.
Introduction. Spondylolisthesis is a progressive disorder leading to the displacement of vertebral bodies relative to one another. In cases of high-grade slippage, surgical treatment is required. However, optimal management remains the topic of ongoing discussion. This study aimed to analyze the early outcomes of surgical treatment in 3 cases of dysplastic spondylolisthesis in adolescents treated at a single center. A retrospective case series involved 3 female adolescent patients who presented with L5–S1 spondylolisthesis with anterior displacement of at least grade III according to the Meyerding classification. All patients underwent surgical reduction of spondylolisthesis and internal fixation. Complications, radiographic findings, quality of life assessed using the SRS-30 questionnaire, and early treatment outcomes were evaluated.
A 3-case report. In the first patient, reduction of the spondylolisthesis with L4–S1 fixation was performed. Approximately 6 months after the primary surgery, S1 implant destabilization was observed, requiring revision surgery consisting of re-stabilization at the L4–S2 levels and augmentation with autologous cancellous bone grafts. The subsequent 2 patients underwent primary fixation from L4 to S2. All patients, bilateral laminectomy and simultaneous posterior lumbar interbody fusion (PLIF) at L5/S1, along with a reduction of the spondylolisthesis. In 1 case, more than a year after the initial procedure, screws had to be removed from the S2 level due to skin conflict. At the follow-up visits performed 1.5 to 4 years after surgery, all patients exhibited sustained reduction of the spondylolisthesis. No implant destabilization or neurological deficits were identified. Patients treated with primary L4–S2 fixation demonstrated higher quality-of-life scores. Reduction of high-grade L5–S1 spondylolisthesis in pediatric patients with fixation from L4 to S2 is an effective surgical treatment method that permits complete correction of vertebral
displacement.
This article presents the biography of Professor Witold Marciniak (1929–2026), an outstanding orthopedist, a master-pupil of Professor Wiktor Dega, and a representative of the Poznań school of orthopedics. He was born in Poznań, Poland, where he spent his entire life, including his professional career. He studied medicine at Masaryk University in Prague and at the Faculty of Medicine of the University of Poznań. From 1989 to 1998 he served as Head of the Department of Pediatric Orthopedics at the Medical Academy in Poznań. Past 2nd president of the Pediatric Orthopedics Section of the Polish Society of Orthopedics and Traumatology of the PTOiTr. (later renamed the Polish Paediatric Orthopaedics Society – PPOS). His primary area of interest was congenital foot deformities, particularly congenital clubfoot.
Application of artificial intelligence (AI) in the automated assessment of hallux valgus on foot radiographs
- 1. Department of Orthopedics and Traumatology, Jagiellonian University Medical College, Kraków, Poland
- 2. Department of Orthopedics and Rheumoorthopedics, Center of Postgraduate Medical Education, Prof. Adam Gruca Independent Public Clinical Hospital, Otwock, Poland
Abstract
Introduction. Radiographic assessment of hallux valgus is based on measurements of the hallux valgus angle (HVA), intermetatarsal angle (IMA), and hallux interphalangeal angle (IPA) on standing anteroposterior foot radiographs. These parameters are important for evaluating deformity severity and planning
surgical treatment. However, semi-automated methods are time-consuming and susceptible to observerdependent variability. AI-based automation may improve measurement reproducibility and facilitate preoperative planning.
Aim. To develop an automated artificial intelligence-based system for measuring HVA, IMA, and IPA on weight-bearing foot radiographs, and to assess the agreement, analysis time, and clinical usefulness of automated measurements compared with semi-automated measurements.
Materials and methods. A total of 265 weight-bearing anteroposterior foot radiographs from patients qualified for surgical treatment were analyzed. After training a neural network for segmentation and labeling of foot bones, with segmentation accuracy expressed by a Sørensen–Dice coefficient > 0.97, reference points were automatically determined, and HVA, IMA, and IPA were calculated. Automated measurements were compared with semi-automated measurements performed by orthopedic surgeons. Agreement, accuracy, and reproducibility were analyzed using the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and Bland–Altman analysis. For IPA, Pearson correlation, mean absolute error, limits of agreement, and measurement time were additionally assessed. Agreement regarding the recommended type of surgical procedure based on HVA and IMA values obtained using both methods was also compared.
Results. Automated measurements showed high agreement with semi-automated measurements. Comparison of the AI system with semi-automated measurements demonstrated high ICC values for HVA (0.97), IMA (0.89), and IPA (0.88–0.92), with corresponding SEM values of 0.26, 0.16, and 1.77°–2.09°, respectively. Bland-Altman analysis showed small systematic biases between methods, amounting to 0.13° for HVA, 1.87° for IMA, and 1.61–2.54° for IPA. For IPA, Pearson correlation coefficients between automated and semi-automated measurements were r = 0.85–0.90 (p < 0.001). Automated IPA assessment in 84 cases took approximately 4.5 minutes, compared with 36 minutes for semi-automated measurements. Agreement between surgical recommendations based on automated and semi-automated HVA and IMA measurements was 0.80.
Conclusions. The developed artificial intelligence-based system enables fully automated, fast, and reproducible measurement of HVA, IMA, and IPA on foot radiographs. The U-Net-based bone segmentation method demonstrated high accuracy and good agreement with clinicians’ assessment, including in cases of
advanced deformity. The system may shorten analysis time, reduce measurement variability, and support clinicians in the diagnosis and surgical planning of hallux valgus.